A sandwich panel for cold room installation
Sandwich panel for cold room uses polyurethane material as the external insulation of small cold storage. There are many problems when installing cold room panel. The following are the details that need attention during the installation of the cold storage.
1. Cold storage hook is an important part of cold storage. When hanging the hook, it should be slowly and evenly forced until the board joint is closed. Excessive force is not allowed to prevent the hook box from pulling out, resulting in a large gap between the boards
2. We all know that the different design of the cold storage leads to the different composition of the cold storage plates. Therefore, when installing the cold storage, we must refer to the cold storage drawing for assembly, to avoid the wrong location of the cold storage plates, causing unnecessary trouble.
3. During the installation of polyurethane cold storage plate, it must be noted that the collision between the storage plate and the storage plate is not allowed during the transportation of the storage plate, which will have a great impact on the overall appearance of the warehouse.
4. After the construction of the warehouse, it is necessary to comprehensively check whether the warehouse seam is too large in some places, fill silica gel in time for sealing, and apply a sealant to the installation of fans, suspenders, and wire holes.